BNLRF - ABLEFILM 566K

  • MSDS: BNLRF
  • Manufacturer: ABLESTIK LABS
  • Product Name: ABLEFILM 566K
  • National Stock Number: 8040-00N027252
Product Identification

Product ID:ABLEFILM 566K
MSDS Date:02/26/1988
FSC:8040
NIIN:00N027252
MSDS Number: BNLRF

Responsible Party
ABLESTIK LABS
20021 SUSANA RD
RANCHO DOMINGUEZ, CA 90221
US

Emergency Phone: 213-764-4600

Info Phone: 213-764-4600

Cage: 9V874

Contractor
ABLESTIK LABS SUB OF NATIONAL STARCH AND CHEMICAL
COMPTON, CA 90221 US

Telephone: 310-764-4600

Cage: 21109

Ingredients

ACRYLONITRILE

CAS: 107-13-1

RTECS: AT5250000

Fraction By Weight: <10% PPM

OSHA PEL SEE 1910.1045

ACGIH TLV: S, 2 PPM;A2 9394

EPA Report Quantity: 100 LBS

DOT Report Quantity: 100 LBS

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:YES IARC:YES OSHA:YES
Health Hazards Acute and Chronic:ACUTE: SEE SYMPTOMS OF OVEREXPOSURE.
CHRONIC: ACRYLONITRILE IS CONSIDERED TO BE CARCINOGENIC.
Explanation of Carcinogenicity:ACRYLONITRILE: ANTICIPATED TO BE A
CARCINOGEN (NTP), GROUP 2B (IARC), OSHA-REGULATED.
Effects of Overexposure:INHAL: NOT LIKELY TO PRODUCE AN ADVERSE EFT DUE
TO ITS LOW VOLATILITY. SKIN: PROLONGED OR REPEATED CONTACT MAY
CAUSE IRRITATION TO SENSITIVE INDIVIDUALS. EYES: SHOULD NOT CAUSE
IRRITATION DUE TO ITS L OW VAPOR PRESSURE. INGEST: INFO IS NOT
AVAILABLE, HOWEVER, SLIGHT POTENTIAL FOR ORAL TOXICITY IS EXPECTED.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

First Aid

First Aid:EYE: FLUSH WITH WATER FOR AT LEAST 15 MIN. SEEK MD ATTENTION.
SKIN: WASH IMMEDIATELY WITH SOAP AND WATER. IF IRRITATION PERSISTS,
SEEK MEDICAL ATTENTION IMMEDIATELY. INHAL: REMOVE TO FRESH AIR
IMMEDIA TELY. INGEST: SEEK MEDICAL ATTENTION IMMEDIATELY.

Fire Fighting

Flash Point Method:COC
Flash Point:>400F,>204C
Extinguishing Media:CARBON DIOXIDE, FOAM, DRY CHEMICAL.
Fire Fighting Procedures:WEAR NIOSH/MSHA APPROVED SCBA AND FULL
PROTECTIVE EQUIPMENT .
Unusual Fire/Explosion Hazard:NONE KNOWN.

Accidental Release

Spill Release Procedures:SWEEP UP AND COLLECT IN AN APPROPRIATE
CONTAINER FOR DISPOSAL.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:STORE FROZEN AT ALL TIMES.
Other Precautions:AVOID CONTACT WITH SKIN, EYES, AND CLOTHING. GOOD
HOUSEKEEPING IS REQUIRED. AVOID INHALATION OF VAPORS.

Exposure Controls

Respiratory Protection:USE NIOSH/MSHA APPROVED ORGANIC VAPOR RESPIRATOR
IF NEEDED.
Ventilation:USE ADEQUATE VENTILATION. LOCAL EXHAUST IS RECOMMENDED WHEN
APPROPRIATE TO CONTROL EMPLOYEE'S EXPOSURE.
Protective Gloves:RUBBER GLOVES.
Eye Protection:CHEMICAL WORKERS GOGGLES .
Other Protective Equipment:PROTECTIVE EQUIPMENT TO COVER EXPOSED AREAS.
Work Hygienic Practices:VENT CURING OVEN TO OUTDOORS.
Supplemental Safety and Health
CNDTNS (POLYM): SHOULD BE USED WITH CAUTION UPON CURING. VENT CURING
OVEN TO OUTDOORS.

Chemical Properties

HCC:N1
Spec Gravity:2.3
Evaporation Rate & Reference:NON-VOLAT SOLID (BUAC=1)
Solubility in Water:INSOLUBLE
Appearance and Odor:WHITE FILM, ODORLESS
Percent Volatiles by Volume:<1(WT)

Stability

Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZING AGENTS AND STRONG LEWIS OR MINERAL ACIDS.
Stability Condition to Avoid:HEAT PRIOR TO CURE.
Hazardous Decomposition Products:CARBON MONOXIDE, ALDEHYDES, AND ACIDS.
POSSIBLE FORMATION OF CYANIDE COMPOUNDS UPON INCOMPLETE COMBUSTION.
Conditions to Avoid Polymerization:EXCESSIVE HEAT. IF PROD IS NOT USED
FOR THIN BLOND LINE APPLICATN, VIOLENT CHEM REACTION CAN RESULT.
PROD (SUPP DATA)

Disposal

Waste Disposal Methods:DISPOSE IN APPROVED CHEMICAL DISPOSAL AREA OR IN
A MANNER WHICH COMPLIES WITH ALL LOCAL, STATE AND FEDERAL
REGULATIONS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their